The device can only be reset by a hardware reset on the device itself.

Procedure
  1. Move the configuration switch to the Rst position, hold it there and press the reset button at the same time.

    The reset button can be pressed with a suitable object (e. g. ballpoint pen).

    After a reset, the device restarts and the status indicators flash.

    Device and module configurationare reset.

  2. You can release both the reset button and the configuration switch again.

    The configuration switch returns to the Static position.

  3. Set the configuration switch for user-defined IP settings to the Cfg switch position.

Device configuration after reset

Owner:

none

Device name:

ibaW-xxxxxx

xxxxxx = 6-digit serial number, e. g. ibaW-000046 The serial number can be found on the type label

IP address:

192.168.1.1

Subnet mask:

255.255.255.0

Gateway:

0.0.0.0

DHCP:

no