The following system requirements are necessary for the use of the SINUMERIK-Xplorer data interface:
-
ibaPDA v8.13.0 or higher
-
Base license for ibaPDA + license for ibaPDA-Interface-SINUMERIK-Xplorer
-
For more than 16 SINUMERIK NCUs (Numerical Control Unit), you need additional one-step-up-Interface-SINUMERIK-Xplorer licenses each additional 16 connections.
-
Siemens SINUMERIK ONE or SINUMERIK CNC control type 840D sl (Solution line) or 840D pl (Power line) or 828D sl (Solution line)
-
SIMATIC NET or SIMATIC STEP 7 in case of connecting via SIMATIC NET communication board (CP)
For further requirements for the used computer hardware and the supported operating systems, refer to the ibaPDA documentation.
System constraints
Regarding the number of connections, the following technical constraints apply:
The number of S7-, SINAMICS- and SIMOTION-Xplorer connections is limited to 240. TCP and PC/CP connections of the SINAMICS-, SIMOTION- and SINUMERIK-Xplorer are evaluated differently. A SINAMICS-, SIMOTION- or SINUMERIK-Xplorer connection over TCP only counts 1/16. A PC/CP connection is calculated in full.
This means:
Number of S7-Xplorer connections
+ number of SINAMICS-Xplorer-TCP connections not routed / 16 1)
+ number of SIMOTION-Xplorer-TCP connections not routed / 16 1)
+ number of SINUMERIK-Xplorer-TCP connections not routed / 16 1)
+ number of SINAMICS-Xplorer-TCP connections routed
+ number of SIMOTION-Xplorer-TCP connections routed
+ number of SINAMICS-Xplorer-PC/CP connections
+ number of SIMOTION-Xplorer-PC/CP connections
+ number of SINUMERIK-Xplorer-PC/CP connections
≤ 240!
1) Only active connections are taken into account. The division must always be rounded to the next larger number. (One connection resource per started 16 connections.)
Access to the SINAMICS Control Units which are integrated in the SIMOTION controls is not supported.
License information
|
Order No. |
Product name |
Description |
|---|---|---|
|
31.000033 |
ibaPDA-Interface-SINUMERIK-Xplorer |
Extension license for an ibaPDA system adding the data interface SINUMERIK-Xplorer (interface for up to 16 SINUMERIK NCUs) with 16 connections. |
|
31.100033 |
one-step-up-Interface-SINUMERIK-Xplorer |
Extension license for another 16 SINUMERIK NCUs (max. 15 extension licenses) |
Note |
|
|---|---|
|
To use more than 16 data connections per interface, you can purchase the one-step-up-… extension licenses separately for each interface. Up to 16 further connections to SINUMERIK NCUs can be established on each one-step-up-license. Up to 256 connections can be configured and used per data interface with the multiple purchase or multiple release of these licenses (up to 15 in total). |
|