Number

3

Version

Galvanically isolated, single ended

2 A/D converters per channel (ibaMS3xAI-1A/100A only)

Resolution

16 bit (18 bit internal)

Filters

permanent

in addition

R/C low-pass, 1st order, 40 kHz

Analog anti-aliasing filter (Butterworth), 4th order, 20 kHz

Digital anti-aliasing filter (Chebyshev I)1, 8th order, cutoff frequency adjustable

ibaMS3xAI-1A

ibaMS3xAI-5A

ibaMS3xAI-1A/100A

Input signal range

-3.0 A … +3.0 A

-15.0 A … 15.0 A

-6.25 A … +6.25 A

-100 A … +100 A2

Max. input current

±10.5 A

±24 A

±24 A (permanent)

±100 A (only for 1 s per minute)

±500 A (briefly for 0.2 s per 5 minutes)3

Measuring shunt

25 mΩ

5 mΩ

2x 5.0 mΩ

Input resistance

Device switched off

25 mΩ

5 mΩ

2.5 mΩ

Device switched on

25 mΩ

5 mΩ

2.5 mΩ

Input capacity

n/a

n/a

n/a

Sampling rate

max. 40 kHz, freely adjustable

Frequency range

0 Hz to 20 kHz

Accuracy

< 0.1 % of total measuring range

Electrical isolation

Channel-channel

Channel - housing/power supply

2.5 kV AC

2.5 kV AC

Connector type inputs

8-pin connector, clamp-type terminal (0.5 mm2 …10 mm2) and interlocking device, included in delivery, without jumper