The measuring ranges are only valid for the ibaMS3xAI-1A/100A module. The internal 18 bit processing of the ibaMS3xAI module allows to display different measuring ranges in high resolution with 16 bit.

Measuring range

Resolution

Calibrated

Analog filter

Description

1.56 A

16 bit

x

x

for currents < 1.56 A DC

6.25 A

16 bit

x

x

default

100 A

16 bit

x

-

for currents < 100 A DC (only for 1 second)

6.25 A / 100 A

15 bit

x /x

x / -

combined range with 6.25 A and 100 A range. Switch-over at 6.20 A.