Digital outputs

Number

32

Design

8 galvanically isolated roots of 4 outputs each, P switch

Load voltage

24 V DC, external per channel, reverse-polarity protected

Load voltage range

+ 10 V…+ 30 V

Switching voltage per channel

= Load voltage

Switching current per channel

250 mA

Switching current range per channel

10 mA … 500 mA

Inductive load

Max. 200 mJ

Switching frequency

max. 40 kHz1, freely adjustable

Switching delay

Switch-on delay (90% to 10%)

< 10 μs

Switch-off delay (10% to 90%)

< 10 μs at 24 V switching voltage with a 100 Ω load

Electrical isolation

Root-root

1.5 kV AC

Root-housing/power supply

1.5 kV AC

Connector type

4x 12-pin multi-pin connector, screw-type terminal (0.14 mm2 to 1.5 mm2), included in delivery

Protective functions

Safe state

channel root switched off

Current limitation

Starting at approx. 0.6 A per channel, the channel root is switched to "safe state" (can be reset via software)