Digital outputs

Number

16

Design

galvanically isolated, 2-wire system, switch

Load voltage

0 V … +55 V

Switching current (per channel)

10 mA …2 A

Switching frequency

0 Hz ... 5 kHz1

Switching delay

<10 µs

Output impedance

typ. 0.1 Ohm

Electrical isolation

Channel-channel

2.5 kV AC

Channel - housing/power supply

2.5 kV AC

Connection type

2 x 16-pin multi-pin connector; clamp-type terminal (0.2 mm2 to 2.5 mm2), screw connection, included in delivery

Protective functions

Safe state

Open switch

Current limitation

25 A (peak)

Reverse voltage limitation

appr. -1 V

Overvoltage limitation

+60 V

Overtemperature protection

from 150 °C

Permanent overcurrent protection

min. >2.0 / typ. 2.3 / max. <2.7A

Surge current protection

Channel inactive at an impulse of appr. 3 A x 80 ms/

5 A x 33 ms/ 10 A x 15 ms/20 A x 7 ms

Fire protection

4 A lead fuse