Number

16

Design

electrically isolated, protected against reverse polarity, single ended

ibaMS16xDI-24V

ibaMS16xDI-220V

Input signal

24 V DC

220 V DC

Max. input voltage

±60 V permanent

±300 V for 1 minute

Signal level log. 0

> -6 V; < +6 V

> -56 V; < +56 V1

Signal level log. 1

< -10 V; > +10 V

< -76 V;> +76 V2

Hysteresis

none

none

Input current

1 mA, constant

Debounce filter

optional: 4 operating modes

Sampling rate

up to 40 kHz, freely adjustable

Frequency range

0 Hz to 20 kHz

Delay

typ. 10 µs

Electrical isolation

Channel-channel

2.5 kV AC

Channel-housing/power supply

2.5 kV AC

Connection type

2x 16-pin multi-pin

connector; clamp-type terminal (0.2 mm2 to 2.5 mm2), screw connection, included in delivery