Danger! |
|
|---|---|
|
Electric shock If the device is used or operated in a manner other than specified in the Technical data chapter, the protection supported by the device may be impaired. |
|
Danger! |
|
|---|---|
|
Class 1 laser product Observe basic safety measures with regard to laser radiation when operating this device. Avoid looking directly into the laser light, especially with optical instruments. |
|
|
Short description |
|
|
Name |
ibaM-FO-2IO |
|
Module label |
FO-2IO |
|
Description |
fiber optic interface module for ibaNet 32Mbit |
|
Order number |
10.182000 |
|
Module-module interface |
|
|
Number |
2 |
|
Connection technology |
4x 8 sliding contacts |
|
ibaNet interface |
|
|
Number |
2 |
|
Design |
optical fiber |
|
Protocol |
ibaNet 32Mbit Flex (bidirectional) ibaNet 32Mbit (fixed) |
|
Data transfer rate |
32 Mbit/s |
|
Sampling rate |
up to 100 kHz, freely adjustable, determined by partner |
|
Connection technology |
2x 2 ST-connectors each for RX and TX; iba recommends the use of FO with multimode fibers of type 50/125 μm or 62.5/125 μm; For information on cable length, see chapter Example for FO budget calculation |
|
Transmitting interface (TX) |
|
|
Output power |
50/125 µm FO cable: -19.8 dBm to -12.8 dBm |
|
62.5/125 µm FO cable: -16 dBm to -9 dBm |
|
|
100/140 µm FO cable: -12.5 dBm to -5.5 dBm |
|
|
200 µm FO cable: -8.5 dBm to -1.5 dBm |
|
|
Temperature range |
-40 °F to 185 °F (-40 °C to 85 °C) |
|
Light wavelength |
850 nm |
|
Laser class |
Class 1 |
|
Receiving interface (RX) |
|
|
Sensitivity 1 |
100/140 µm FO cable: -24 dBm to -10 dBm |
|
Temperature range |
-40 °F to 185 °F (-40 °C to 85 °C) |
|
Supply |
|
|
Supply voltage |
24 V DC via module-module interface |
|
Current consumption (max.) |
|
|
Own consumption |
0.1 A |
|
Input/output current |
4 A |
|
Further interfaces, operating and indicating elements |
|
|
Indicators |
LEDs for operation and errors |
|
Operating and environmental conditions |
|
|
Temperature range |
|
|
Operation |
14 °F to 131 °F (-10 °C to +55 °C) |
|
Storage |
-13 °F to 185 °F (-25 °C to +85 °C) |
|
Mounting |
on DIN rail according to EN 50022 (TS 35, DIN Rail 35) |
|
Cooling |
passive |
|
Relative humidity |
15 % … 95 % (indoor), no condensation |
|
Operating altitude |
0 m ... 2000 m above sea level |
|
Protection type |
according to IP20; without test certificate according to IEC 60529 |
|
Certifications / standards |
CE, C-Tick, UKCA, FCC, KC, IEC 61010-1, IEC 61000-6-5 Interface range 4 |
|
Pollution degree |
2 |
|
MTBF2 |
1,659,212 hours / 189 years |
|
Dimensions |
|
|
Width x height x depth |
28 mm x 133 mm x 131 mm |
|
Height with open lever |
160 mm |
|
Height units |
3 |
|
Installation clearances |
|
|
Bottom / top |
30 mm / 30 mm |
|
Left / right (system) |
10 mm / 10 mm |
|
Mounting position |
vertical, lever up |
|
Weight / incl. packaging |
0.24 kg / 0.47 kg |
|
Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information Unique Identifier: 10.182000, ibaM-FO-2IO Responsible Party - U.S. Contact Information iba America, LLC 370 Winkler Drive, Suite C Alpharetta, Georgia 30004 (770) 886-2318-102 www.iba-america.com FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. |