Caution! |
|
|---|---|
|
You must only connect one conductor to each terminal connection. Several individual conductors, whether single-wired or fine-wired, are not permitted. Only connectors classified by iba may be used for connecting conductors. |
|
|
Connection technology |
Push-in |
||||
|
Clamping range |
0.08 - 2.5 mm2 |
||||
|
Conductor cross-section |
|||||
|
Single-wired |
0.5 - 1.5 mm2 |
||||
|
Fine-wired |
0.5 - 2.5 mm2 |
||||
|
With wire end ferrule |
0.5 - 2.5 mm2 |
||||
|
With wire end ferrule/collar |
0.5 - 2.5 mm2 |
||||
|
Stripping length |
|||||
|
Cross-section |
0.5 mm2 |
0.75 mm2 |
1 mm2 |
1.5 mm2 |
2.5 mm2 |
|
Single-wired |
10 mm |
||||
|
Fine-wired |
|||||
|
With wire end ferrule |
10 mm |
||||
|
With wire end ferrule/collar |
12 mm |
n/a |
|||
|
Recommended cables |
|||||
|
Single-wired |
H05V-U; H07V-U |
||||
|
Fine-wired |
H05V-K; H07V-K |
||||
|
Screwdriver blade |
0.6 mm x 3.5 mm |
||||
Caution! |
|
|---|---|
|
Measuring cable
|
|