Analog inputs
|
Number |
4 |
|
Design |
galvanically isolated, single ended, 2 A/D converters per channel |
|
Input signal / nominal current |
5 A AC |
|
Resolution |
24 Bit (Delta-Sigma) |
|
ADC sampling rate |
500 kHz |
|
ibaPDA timebase (update time) |
min. 2 μs; freely adjustable (integer multiple); max. 1 ms for filter signals |
|
Filters |
|
|
ADC signal |
|
|
analog |
R/C low-pass, 1st order, 150 kHz |
|
digital |
anti-aliasing filter (FIR), 84th order; cutoff frequency = 0.45 x ADC sampling rate; oversampling = 32 x ADC sampling rate |
|
Filter signal1 |
|
|
Like ADC signal, in addition: |
|
|
digital |
anti-aliasing filter (Elliptic/Cauer); 10th order; cutoff frequency = 0.45 / timebase |
|
Protection factor / overload current |
30 x nominal current |
|
Nominal measuring range |
±15 A |
|
Measurable overload range2 |
-225 A … -15 A / +15 A … +225 A |
|
Input current max. |
15 A DC; permanent |
|
In overload range |
150 A AC; transient for 1 s per minute3 |
|
Input voltage max. |
CAT III 600 V / CAT IV 300 V |
|
Measuring shunt |
2.0 mΩ |
|
Input resistance |
|
|
Device switched off |
2.0 mΩ |
|
Device switched on |
2.0 mΩ |
|
Input capacity |
n/a |
|
Accuracy (+25 °C)4 |
|
|
Nominal measuring range |
< 0.1 % of double nominal measuring range end value |
|
Overload range5 |
< 0.1 % of double overload range end value |
|
Electrical isolation |
|
|
Channel - channel |
basic insulation: CAT III 600 V |
|
Channel - system |
reinforced insulation: CAT III 600 V |
|
Connection technology |
2x 4-pin pin header, pitch 7.62 mm |
|
Connector |
2x enclosed; push-in, conductor max. 6 mm2, locking lever (latching), protected against reverse polarity, lockable, screw-on, without jumper; For information on the conductor and stripping length, see chapter Connection technology connector ; Order number: 52.000051 |
Additional functions
|
Phasor measurement unit6 |
integrated |
|
Power frequency measurement (10 Hz ... 80 Hz) |
interval: 1 s / 10 s (according to IEC 61000-4-30) |