The following table gives an overview of the available operation modes, link speed, number of signals, data sampling time and typical devices:
Protocol |
Max. number of signals per FO link |
Sampling time |
Typical device |
---|---|---|---|
Single fiber input-only modes |
|||
2Mbit |
32 INT + 32 Digital |
≥1 ms |
ibaPADU16/32 (old, S/N < 1000) |
3Mbit |
64 INT + 64 Digital |
≥1 ms |
ibaPADU8/16/32 |
64 REAL + 64 Digital |
≥1 ms |
ibaLink-SM-64-i-o |
|
5Mbit |
8 INT + 8 Digital |
≥50 µs |
SIMATIC TDC LO5 |
32Mbit |
64 INT + 64 Digital |
≥50 µs |
SIMATIC TDC LO6 |
128 INT + 128 Digital |
≥100 µs |
SIMATIC TDC LO6 |
|
512 REAL + 512 Digital |
≥800 µs |
ABB AC 800PEC (1 ms) |
|
DPM-S mode |
≥800 µs |
ibaBM-DPM-S (1 ms) |
|
8 x (64 INT + 64 Digital) |
≥1 ms |
ibaBM-COL-8i-o (1 ms) |
|
Bidirectional fiber modes (output link required) |
|||
5Mbit |
8 INT + 8 Digital |
≥40 µs |
ibaPADU-8-M ibaPADU-8-ICP |
32Mbit Flex |
variable* |
≥10 µs |
ibaPADU-S-CM |
Single fiber output-only modes (output link required) |
|||
3Mbit |
64 REAL + 64 Digital |
≥1 ms |
ibaNet750-BM |
32Mbit |
Not supported by PC software yet. |
* Example: Payload transmission of 64 Byte at 25 µs sampling time or 3100 Byte at 1 ms.
Besides the mere hardware parameters the usability of board and devices in combination with a certain operational mode depends also on the iba software application.
Not all of iba application software products support all modes or cards at the time.
The following table shows the supported combinations of modes of operation and software applications:
Protocol |
3Mbit |
5Mbit |
32Mbit |
32Mbit Flex |
||||
Transmission rate |
3.3 Mbit/s |
5.0 Mbit/s |
32 Mbit/s |
32 Mbit/s |
||||
Sampling rate |
1 Hz -1 kHz |
0.5 kHz - 25 kHz |
1.25 kHz - 20 kHz |
0.5 kHz - 100 kHz |
||||
Number of signals per FO link |
64 A + 64 D |
8A + 8D |
512 A + 512 D (1 ms) 64 A + 64 D (50 µs) |
Up to 4060 bytes |
||||
Application |
Input |
Output |
Input |
Output |
Input |
Output |
Input |
Output |
ibaPDA |
■ |
□ 1) |
■ |
- |
■ |
- |
■ |
■ |
ibaLogic |
■ |
■ |
- |
- |
■ |
■ |
- |
- |
■ = Ok, □ = possible, - = not supported
1) Alarm outputs (50 ms) via ibaFOB-4o-D, -io-D, -2io-D
Note |
|
---|---|
![]() |
The cards are not supported by ibaScope and ibaLogic-V3. If you need spare boards for these software applications, please contact iba support. |