ibaOut-State provides an output (6-pin connector) which can be used to indicate errors. Both error types are indicated separately.

These are the switch positions:

Switch

status

switch

status



Power OK,

temperature OK



Power off or

Power error and

overtemperature



Power error

temperature OK



Power OK,

overtemperature

Contact loading capacity

Nominal current: 300 mA

Nominal voltage: 220 V DC

Compatibility to previous ibaRackline models

The behavior of ibaOut-State is identical with the previous models with a relay output, if pin 5 and 6 are used. The relay contact of the previous ibaRackline models is closed when an error occurs, without differentiating between overtemperature or a power supply error.