ibaOut-State provides an output (6-pin connector) which can be used to indicate errors. Both error types are indicated separately.
These are the switch positions:
|
Switch |
status |
switch |
status |
|---|---|---|---|
|
Power OK, temperature OK |
Power off or Power error and overtemperature |
||
|
Power error temperature OK |
Power OK, overtemperature |
Contact loading capacity
Nominal current: 300 mA
Nominal voltage: 220 V DC
Compatibility to previous ibaRackline models
The behavior of ibaOut-State is identical with the previous models with a relay output, if pin 5 and 6 are used. The relay contact of the previous ibaRackline models is closed when an error occurs, without differentiating between overtemperature or a power supply error.