Place the device only in the location which has the following properties:
-
Stationary
-
Shock-free
-
In the protected room, for example switch cabinet
-
Dust-free and dry environment
-
Even and non-slip base
Danger of electric shock! |
|
|---|---|
|
Before opening the device disconnect it from the mains and pull out the mains plug from the socket equipped with earthing contact! Never use the device with a damaged mains cable! |
|
Warning! |
|
|---|---|
|
Connect the device to one supply voltage only according to specifications on the built-in power supply unit! Always use a socket equipped with earthing contact! Use a terminal strip with overvoltage protection or an uninterruptible power supply (UPS)! Connect the device only to earthed power networks (TN-networks according to VDE 0100 Part 300 or IEC 60364-3)! The operation via ungrounded networks or networks (IT networks) earthed via impedance is not permitted! Never put a damaged device into operation! |
|
Note |
|
|---|---|
|
When installing the device, observe the minimum bending radii of the cables and lines. The mounting clearance must be at least 150 mm from the rear wall.
Ensure sufficient air circulation. |
|