What options are there for visualizing raw data from different products?
Raw data from DAT files can be visualized as measurement signals in three ways:
-
In appended mode, the measurement signals of the DAT files intended for display are displayed in chronological order according to the start time of the measurement signals, alternatively directly one after the other on a relative time axis.
-
In envelope mode, the signals with the same module and signal number are visualized as an envelope curve on a relative time axis in seconds starting with 0.
-
In stacked mode, the signals of the DAT files selected for display are visualized separately but superimposed on a relative time axis in seconds starting with 0.
For additional information, see Options.