The following settings are preset for ibaDAQ with Win10 LTSC 2021/v21H2 on delivery:
Network parameters
Default settings for rotary switch = 1
Can be configured via rotary switch, see chapter Rotary switch S1.
Network connection X21 |
DHCP active |
Network connection X22 |
DHCP active |
Hostname |
daq-xxxxxx xxxxxx = 6-digit serial number, e. g. daq-000002 The serial number can be found on the type label. |
User accounts
User |
Password |
Rights |
---|---|---|
daq |
iba.SNxxxxxx xxxxxx = 6-digit serial number The serial number can be found on the type label, e. g. iba.SN000036 |
Administrator |
Note |
|
---|---|
![]() |
After 5 times of incorrect password entry, the login function is blocked for 30 minutes. |
Each system installation also creates an administrator account (without password) by default. However, the account is not visible. To make the account visible, proceed as follows:
-
Run cmd as administrator
-
net user administrator /active:yes
-
Start menu - account screen - "Administrator" account
Note |
|
---|---|
![]() |
Change the preset passwords after you have started up ibaDAQ. This makes unauthorized use of the system more difficult. |
Other system settings
-
Auto login is disabled
-
The Windows "Account Lockout Threshold” feature is enabled: After 5 times of incorrect password entry, the login function is blocked for 30 minutes.
-
The ScreenSaver lock is set to 5 minutes and password entry.
These settings can only be changed at the operating system level, either via a remote desktop connection or when input devices (monitor, mouse, keyboard) are connected directly.