You make settings for the report server here.
Web service URL
Enter the web service URL for the reporting server here. You can find this URL in the Microsoft Report Server Configuration Manager on the Web service URL tab.
Domain
The domain address of the report server.
User
The user name to be used for logging into the report server.
Password
The password must contain at least six letters and one number.
Report settings
Under Report settings, the header for the report and various other settings can be defined.
Header
Defines the header information for the reports.
Image / Company logo
A header image for the reports can be selected here. JPG and PNG files are permitted. An image in JPEG format with 150 px * 50 px resolution is recommended for best results. The image is saved as a “base64” string.
The following information is only relevant for ibaCMC v1:
Sensor defect min. class factor
Specifies the minimum classification factor that is required to reach the “Sensor defect” status. The status report is then included in the “Sensor defect” table. Valid values:
-
0 - Normal
-
0.7 - Alert
-
1.0 - Alarm
-
2.5 - Acute alarm
Sensor defect min. percent
Specifies the minimum number of times the value is exceeded as a percentage of the total number. The minimum must be reached for a “Sensor defect” status to be included in the “Status report” [“Sensor defect” table].
Sensor overview min. class factor
Specifies the minimum classification factor that a state has to achieve to be included in the ‘Status overview’ table in the status report. Valid values:
-
0 - Normal
-
0.7 - Alert
-
1.0 - Alarm
-
2.5 - Acute alarm.
Sensor overview min. percent
Specifies the minimum number of times the value is exceeded as a percentage of the total number. The minimum must be reached for a status to be included in the “Status report” [“Status overview” table].
Trend calculation status time domain
Trends that have NOT been calculated in this time range [in hours], are included in the “Trend calculation status” report.