In addition to vibration-based condition monitoring using iba hardware, in ibaCMC hydraulic condition monitoring based on the microCMU is also possible. This microCMU is integrated into ibaCMC as a data source.
The available options are:
-
Unit Fluid Monitoring (UFM), e.g. for oil level monitoring, particle monitoring, and wear monitoring
-
Rotary distributor leakage monitoring (RDM)
-
Cylinder leakage monitoring (CLM)
To add a data source to the plant tree, an aggregate group must first be created. The relevant data source, e.g. UFM, can then be dragged to it.
General
ID
This value is generated automatically by the database and cannot be changed.
Order
This value indicates the order of the display within the same level of the plant tree.
Name
The name of the asset (e.g. plant, aggregate group, aggregate, etc.) can be changed here.
Comment
The Comment field is used to enter comments about an asset. The input field can be enlarged by dragging (bottom right).
Type
Shows the data source type, taken from the data source (e.g. UFM, CLM, RDM)
Host address
Enter the IP address of the data source here.
FTP port, Path, User, Password
The FTP settings for the microCMU cannot be edited using the button, they are only displayed.
Ignore/check measurement condition
The <Ignore measurement condition> button sets whether data is imported from the microCMU and used to create a trend if the measurement condition is not active.
-
Ignore measurement condition: Data is always recorded even if the measurement condition is not active.
-
Check measurement condition: Data is only recorded if the measurement condition for the microCMU is met.
Configuration
Once the IP address entry has been confirmed with <OK>, the connection can be checked.
-
Try connection: Checks the network connection to the microCMU. If the connection is successful, you can continue with synchronization.
-
Synchronize configuration: If the configuration on the microCMU has been changed, this button enables it to be synchronized in ibaCMC.
-
Unlink: Cancels the connection between the microCMU and the server. No more data is imported.
Logs
The logs generated by the data source are displayed here.