To use the compatibility mode 3Mbit (DP-64 mode), set the rotary switches as follows: S1 = 0 and S2 = 0
With this setting, the device replaces the predecessor devices ibaBM-DPM-S-64, ibaBM-DPM-64 and DPM64. The devices can be used for data acquisition with ibaPDA, but also as system coupling without ibaPDA.
In this mode, the device provides up to 2 slaves, which can be operated in different modes. Up to 64 analog and 64 digital values can be transmitted in 1 ms. A sniffer function is not available.
The device can be operated in DP-64 mode also with an older ibaFOB-S or ibaFOB-X card.
For further information see chapter Data acquisition compatibility mode 3Mbit (DP-64 mode) and chapter Compatibility mode 3Mbit (DP-64 mode).