The following table gives an overview of the operating modes which are available on the device. For each mode you’ll find the appropriate GSD files in the corresponding row. Details information can be found in the following chapters.
|
Mode |
Name |
Outputs |
Inputs |
GSD-file |
Application |
|---|---|---|---|---|---|
|
0 |
PDA 32 Integers |
2 * 32 analog (int) 2 * 32 digital |
- |
ibaF01n4.gsd ibaF01n3.gsd iba_0F01.gsd |
ibaPDA, ibaLogic, SIMATIC S7 System coupling |
|
1* |
PDA 32 Reals |
2 * 32 analog (Real) 2 * 32 digital |
- |
iba_0F02.gsd |
ibaPDA, ibaLogic, System coupling No S7*, SD |
|
2 |
n/a |
- |
- |
- |
- |
|
3 |
PDA 28 Reals |
2 * 28 analog (Real) 2 * 32 digital |
- |
ibaF04n4.gsd ibaF04n3.gsd iba_0F04.gsd |
ibaPDA, ibaLogic, System coupling |
|
4 |
n/a |
- |
- |
- |
- |
|
5 |
INPUT 32 Integers |
(4 byte reserved) |
2 * 32 analog (int) 2 * 32 digital |
ibaF00n4.gsd ibaF00n3.gsd |
ibaLogic, S7 System coupling |
|
6* |
INPUT 32 Reals |
(4 byte reserved) |
2 * 32 analog (Real) 2 * 32 digital |
iba_0F06.gsd |
ibaLogic, System coupling no S7*, SD |
|
7 |
INPUT 28 Reals |
(4 byte reserved) |
2 * 28 analog (Real) 2 * 32 digital |
ibaF07n4.gsd ibaF07n3.gsd |
ibaLogic, S7 System coupling |
|
8 |
IN-OUT 32 Integers |
2 * 32 analog (int) 2 * 32 digital |
2 * 32 analog (int) 2 * 32 digital |
ibaF08n4.gsd ibaF08n3.gsd iba_0F08.gsd |
ibaLogic, S7 System coupling |
|
9* |
IN-OUT 32 Reals |
2 * 32 analog (Real) 2 * 32 digital |
2 * 32 analog (Real) 2 * 32 digital |
iba_0F09.gsd |
ibaLogic, System coupling no S7*, SD |
|
A |
n/a |
- |
- |
- |
- |
|
B |
IN-OUT 28 Reals |
2 * 28 analog (Real) 2 * 32 digital |
2 * 28 analog (Real) 2 * 32 digital |
ibaF0Bn4.gsd ibaF0Bn3.gsd |
ibaLogic S7 System coupling |
* not applicable to former CPUs SIMATIC S7 (firmware <2.0 for S7-300, firmware < 3.0 for S7400) or SIMADYN D
Note |
|
|---|---|
|
Note the meaning of the terms "output" and "input". These refer to the PROFIBUS master device. For example, "Output" means that data is sent from the PROFIBUS master device (e. g. SIMATIC S7) to the ibaBM-DP device. Both slaves in the ibaBM-DP are always used in the same mode. |
|
The file names of the GSD files which come with our PROFIBUS products had been renamed for standardization purposes (eff. 10/2005).
If you still use the old files, please refer to the following table for reference:
|
New GSD file name |
Old GSD file name |
|---|---|
|
ibaF01n4.gsd |
DPM32IO.GSD |
|
ibaF01n3.gsd |
DPL32IO.GSD |
|
iba_0F01.gsd |
L2B_32I.GSD |
|
iba_0F02.gsd |
L2B_32R.GSD |
|
ibaF04n4.gsd |
DPM28RO.GSD |
|
ibaF04n3.gsd |
DPL28RO.GSD |
|
iba_0F04.gsd |
L2B_28R4.GSD |
|
ibaF00n4.gsd |
DPM32II.GSD |
|
ibaF00n3.gsd |
DPL32II.GSD |
|
iba_0F06.gsd |
L2B32RI.GSD |
|
ibaF07n4.gsd |
DPM28RI.GSD |
|
ibaF07n3.gsd |
DPL28RI.GSD |
|
ibaF08n4.gsd |
DPM32IOI.GSD |
|
ibaF08n3.gsd |
DPL32IOI.GSD |
|
iba_0F08.gsd |
L2B32IOI.GSD |
|
iba_0F09.gsd |
L2B32ROI.GSD |
|
ibaF0Bn4.gsd |
DPM28ROI.GSD |
|
ibaF0Bn3.gsd |
DPL28ROI.GSD |
Note |
|
|---|---|
|
The GSD files required for the DP-64 mode can be found on the "iba Software & Manuals"
data carrier in the directory |
|