Short description |
|||
|
Name |
ibaBM-DDCS |
||
|
Description |
Bus monitor for DDCS drive bus |
||
|
Order number |
13.120710 |
||
|
DDCS interface |
|||
|
Number |
3 for one DDCS drive bus |
||
|
Connection technology |
2 HBFR Versatile Link connector (1 mm POF) for RX and TX, simplex, duplex, without interlocking (per link) |
||
|
Typical application |
Link0: Connected with control (only Rx is used here) Link1: Connected with measurement interface of the drives Link2: Connected to computer with DriveWindow for configuration and measurement, if required |
||
|
ibaNet interface |
|||
|
Number |
1 (e. g. for the connection to ibaPDA) |
||
|
ibaNet protocol |
32Mbit Flex |
||
|
Data transfer rate |
32 Mbit/s |
||
|
Sampling rate |
max. 40 kHz, freely adjustable |
||
|
Connection technology |
2 ST connectors for RX and TX; iba recommends the use of FO with multimode fibers of type 50/125 μm or 62.5/125 μm; For information on cable length, see chap. . Example for FO budget calculation |
||
|
Transmitting interface (TX) |
|||
|
Output power |
50/125 µm FO cable |
-19.8 dBm to -12.8 dBm |
|
|
62.5/125 µm FO cable |
-16 dBm to -9 dBm |
||
|
100/140 µm FO cable |
-12.5 dBm to -5.5 dBm |
||
|
200 µm FO cable |
-8.5 dBm to -1.5 dBm |
||
|
Temperature range |
-40 °F to 185 °F (-40 °C to 85 °C) |
||
|
Light wavelength |
850 nm |
||
|
Receiving interface (RX) |
|||
|
Receiving sensibility1 |
100/140 µm FO cable |
-33.2 dBm to -26.7 dBm |
|
|
Temperature |
-40 °F to 185 °F (-40 °C to 85 °C) |
||
|
Further interfaces, operating and indicating elements |
|||
|
Power supply |
+24 V DC ±10 % not stabilized 2-pin connector, clamp-type terminal (0.2 mm2 to 2.5 mm2), screw connection, included in delivery |
||
|
Power consumption |
max. 15 W |
||
|
Rotary switch |
Device address (in the cascade) |
||
|
Indicators |
4 LEDs for operating status of the device 8 LEDs for channel status |
||
|
Operating and environmental conditions |
|||
|
Cooling |
passive |
||
|
Operating temperature |
-40 °F to 185 °F (0 °C to 50 °C) |
||
|
Storage and transport temperature |
-40 °F to 185 °F (-25 °C to 70 °C) |
||
|
Humidity class acc. to DIN 40040 |
F, no condensation |
||
|
Protection class |
IP20 |
||
|
Mounting |
DIN-rail mounting , vertical |
||
|
Norms and standards |
EMC: IEC 61326-1 FCC part 15 class A |
||
|
Dimensions and weight |
|||
|
Dimensions (Width x height x depth) |
2.1 in x 7.4 in x 5.6 in (54 mm x 188 mm x 140 mm), including DIN-rail clip |
||
|
Weight (incl. packaging) |
approx. 2.2 lb (ca. 1.5 kg) |
||