Views |
||
|
Object |
Function |
Application |
|
Bar chart |
Display of signal values as single-bar or multi-bar charts Color change for value ranges, dynamic limits, polynomial calculation for profiles |
General value display Fill levels Profiles |
|
Chart |
Multifunction object for the combined display of trend curves, graphic objects, markers, harmonics and texts as well as several base and value axes |
Machine presentation, layered presentation |
|
FFT view |
Spectrum slave graph of a signal |
Frequency analysis Chatter monitoring |
|
HD event table |
Display a list of events based on an event-based HD data store |
Error and alarm monitoring; search for process events |
|
HD navigation |
Parent toolbar for controlling multiple HD views |
Space-saving control of multiple HD trend graphs |
|
HD time periods table |
Display a list of predefined time periods based on a time-based HD data store |
Facilitate the analysis of recurring process steps or procedures as well as regular periods (day, week, shift) |
|
HD trend graph |
Display historical data in a trend view; connection to any HD-Server in the network |
Comparing data from the past with current values |
|
Camera view |
Display a camera view of an ibaCapture-CAM server on the screen Scenario player screen for event-based camera switching. |
Monitoring Process control Troubleshooting |
|
Circle view |
Relevant parameters for the circle view are derived from the module settings. |
Visualization of the results of the InCycle expert module and the InCycle auto-adapting module for rotating processes |
|
Offline trend graph |
Display a trend graph from a data file (no live data) |
Comparison of older and current measured values, comparison of current values with reference curve |
|
Orbit view |
The orbit itself is the appearance of the X/Y data pair during a (or several) revolution(s) of the shaft |
Results of the orbit calculation are given as analog values of the respective InSpectra orbit module |
|
Scope view |
Display signals in a digital oscilloscope |
Commissioning Troubleshooting |
|
PQU spectrum |
Display of a complete PQU spectrum module |
Spectrum presentation of electrical values with up to 50 harmonics (power quality) |
|
Signal tree |
ibaPDA/ ibaHD signal tree |
Source for signals to be added to a view by drag and drop |
|
Trend graph |
Display signal values in a trend graph X axis time or length-based; automatic 2D top-down view on vector signals |
General value display False color display of profiles (temperature, flatness, etc.) |
|
Watch view |
Display window for signal values |
Monitoring selected signals regarding change of value or status |
|
Phasor view |
Display of a complete PQU phasor module |
Phasor presentation of electrical values in a power grid (power quality) |
|
Cycle view |
Display of special graphs and tables |
Visualization of the results of the InCycle expert module and the InCycle auto-adapting module |
|
Display elements |
||
|
Text digital display |
Display of text signals |
Large and clear display of text in the style of an LED display |
|
Numeric digital display |
Display of signal values as numbers, maintaining the positive and negative peak value (resettable) |
Large, clear display of signal values |
|
Gauge panel |
Display of signal values on a classic analog-style gauge Circular, linear and numerical gauges available; numerous design options, free set-up of shape, color, scales and pointers. |
Highlighted value display Replaces traditional displays |
|
Multi-state picture |
Display of various graphics, depending on the signal value |
Status display Security warning |
|
Multi-state label |
Convert a signal value into different states of a label Color change depending on value range(s), text in label |
Status indication |
|
Text field |
Display signal values in a trend graph X axis time or length-based; automatic 2D top-down view on vector signals |
Labeling of the displays Display of the text signal |
|
Input elements |
||
|
Checkbox |
Check box with check mark |
Enabling / disabling options |
|
Input combobox |
Drop-down list with any number of plain text entries. By selecting a list item, a target signal is set to a defined value. |
Manual setting of default values |
|
Button |
Execute commands using a button: Close ibaPDA client; Toggle view; Run command line; Enable application (*.exe); Print (QPanel screen); Digital pulse signal; Set signal value; Trigger value input control; Pause (stop one or all views); Start (continue one or all views); Load layouts from server; Save layouts on server; Open user management; Connect to ibaPDA server; Connect to ibaHD server; Change language; Log out from ibaPDA server; Log out from ibaHD-Server; Change unit system; Switch ibaPDA user; Switch ibaHD user; Commands can be run manually or via signal edges; button text and graphics can be adjusted. |
Control of QPanel display Execution of other applications or scripts |
|
File picker |
Shows the contents of a folder in order to select a file. Name of the selected file is written into a text signal. |
Interactive load of a data file in an offline trend curve |
|
File scanner |
Monitors contents of a folder for automatic selection of the last, second to last, third to last (and so on) file. Name of the selected file is written into a text signal. |
Automatic display and update of the last x data file(s) in offline trend curves |
|
Numeric up/down |
The numerical value of an analog destination signal can be changed either by clicking buttons (+/- or up/down), turning the mouse wheel or typing in. |
Quick, safe and easy way to change a value |
|
Option field |
Group of radio buttons |
Selection of alternative options, operating mode selection |
|
Switch |
On/off switch; switch appearance can be determined by graphics file. Separate graphics for ON, OFF, disabled ON and disabled OFF state possible. Digital target signal. |
Switch functions on/off |
|
Slider |
Slider’s appearance (scale style, orientation, color of background/handle, min/max values etc.) can be configured. |
Control element to display values within a scale |
|
Value input control |
String or value entry for a text signal or numeric signal. This control replaces the former text input control. There is a conversion function available to convert text input controls in older QPanels into value input controls. |
Signal value or additional information on data file, printout, further applications, etc. |
|
Visuals/Layout |
||
|
Image |
Embed a graphic object, optionally statically, dynamically (image file name with wildcards) or by order (controlled by folder monitoring) |
Process or system presentation |
|
Shape |
Basic geometric shapes (line, rectangle, ellipse, polygon); filling and line configurable, optional flashing mode |
Simple shapes, animation |
|
Tabbed layouts |
Summary of multiple ibaQPanel views and layouts with control over tabs. |
Clearer and simpler operation of multiple ibaQPanel layouts |
|
Symbol |
Integration of vector graphics (.svg) with option to change the line color and thickness, fill color, rotation and scaling |
Use of vector graphics |
|
Web |
||
|
Web browser |
Display web pages, PDFs and other browser-fitting files; download of files |
Display data from ibaDaVIS |