This profile type is used to record measured values in a length-based ibaHD data storage. It determines at what intervals (meters) measured values are written in an ibaHD store. The conversion of measured values to a length base is configured in the definition of the ibaHD data storage.

Profile properties

Type

Display of the profile type with the appropriate types of data store (symbols)

Name

Enter an unambiguous and understandable name here.

Length

Adjust the length of the section interval here, at which a measured value should be recorded. The default setting is 1 m.

Filter

Select which value of a signal, related to the set distance interval, is to be stored in the record.

  • None: The actual value will be stored

  • Average: The arithmetic average of all measured values, which were acquired in the interval (according to the time base, such as 1 m or 10 m) is formed and saved.

  • Min: Only the smallest value of all samples measured within the defined interval will be stored.

  • Max: Only the largest measured value of all measured values acquired within the defined interval will be stored.