InterruptTime('Type=0*')

Arguments

'Type*'

Optional parameter (default = 0), with which the type of the result value can be determined.

'Type' = 0

The actual value is returned.

'Type' = 1

The minimum (smallest duration measured) is returned.

'Type' = 2

The maximum (largest duration measured) is returned.

Parameters ending with * are only evaluated once at the start of the acquisition.

Description

This function returns the Interrupt time (Interrupt duration) in microseconds. The value is not updated with each Interrupt, but with a lower cycle.