InterruptCycleTime('Type=0*')
Arguments
|
'Type*' |
Optional parameter (default = 0), with which the type of the result value can be determined. |
|
|
'Type' = 0 |
The actual value is returned. |
|
|
'Type' = 1 |
The minimum (smallest measured cycle period) is returned. |
|
|
'Type' = 2 |
The maximum (largest measured cycle period) is returned. |
|
Parameters ending with * are only evaluated once at the start of the acquisition.
Description
This function returns the Interrupt cycle time in microseconds. The value is not updated with each Interrupt, but with a lower cycle.