FobTDCLinkStatus('BoardNo*')

FobTDCexpLinkStatus('BoardNo*')

Arguments

'BoardNo*'

Board number (0 to 3)

Parameters ending with * are only evaluated once at the start of the acquisition.

Description

This function returns the link status of an ibaFOB-TDC board (PCI) or ibaFOB-TDCexp board (PCIe).

The board number (from 0 to 3) can be obtained from the 7-digit display on the card or the graphical presentation in the I/O Manager. The board only has one link.

Results

0

Link not active

1

Link OK

2

Link interrupted

Prerequisites

This function only returns a value if active input modules are installed and configured in the I/O Manager.