Basic settings
For a description of the basic settings see Common and general module settings.
In contrast to other modules there is no timebase setting for a signal mapper module. The reason is that a signal mapper module does not actually process signals on its own but just maps the signals. The timebases of the input signals are always adopted even if the signals come from different sources with different timebases.
Profile
Select here the profile which should configure this module.
If no profile is available yet, you can switch to the profile configuration dialog by clicking on <New profile...> or <Edit profile...>.
Without a profile a signal mapper module has no signals.
The Analog and Digital tabs are not visible before a profile has been applied.
Source signals
This option determines whether the source signals which are linked to the signal mapper modules are still available in the signal tree or not. Enabling this option (True) prevents the same signal to be recorded twice (first source signal, second mapped signal).
"Configure profiles" link
Clicking on this link opens the configuration dialog for profiles.
Always when you create a module, you can configure a profile. But you can also configure the required profiles first and create the modules later.