Procedure
-
Consider which factors and parameters could have an influence on the process with regard to the planned analysis.For example, wear detection for saw blades with ibaInCycle:
-
Material type of the material to be sawn
-
Saw blade diameter
-
-
Check whether the appropriate signals for mapping these factors are present in the I/O configuration. If not, create them. These can be analog, digital and/or text signals.
-
Define reasonable values or value ranges for these signals.For example, wear detection for saw blades with ibaInCycle:
-
3 material types: 1, 2 and 3
-
Saw blade diameter: 100 … 300 mm
-
-
Add a Process condition module.
-
Create and configure a profile by entering the previously determined process variables in the Inputs table.
-
Select the desired profile in the general module settings.
-
Assign the signals to the now-visible input parameters in the general module settings.
-
To use the process condition, select the desired output signal for the Process condition module as the status signal in the module settings, e.g., for the InCycle Auto-Adapting module.