Procedure
-
Prepare a table with the keys or codes in the left column and the matching values in the right column. It is easier if you already have the table in digital form.
-
Add a "Lookup Table" module under the "Virtual" interface.
-
Configure a profile:
-
Select the data type for the keys.
-
Set a default text for unknown keys.
-
Transfer the table contents to the profile.
-
-
Save the profile and then select it in the general module settings under Table profile.
-
In the general module settings, adjust the number of analog signals depending on how many applications you want to use this lookup table for.
-
Select the Analog tab and give the analog signals a name.
-
In the Key selector column, select the appropriate signal with which the code (key) is transmitted in each case.
-
Click on <OK> or <Apply>.
-
After restarting the acquisition, you see the lookup table module with the analog signals in the signal tree.
-
You can display or process the results like any other signal.