The data interface DGM200P is based on a proprietary communication hardware from GE Energy Power Conversion (ex. Converteam GmbH). The connection is only available for the systems HPC (“Logidyn D”) and HPCi (P80i) when using the quick system bus DGM200. The DGM200P interface is a prerequisite for using the modules HPCi Lite and HPCi Request.
The following hardware components are required:
-
at least one DGM200V board in an HPC/HPCi rack or one DGM200P board in an HPCi PC
-
in case of multiple HPC/HPCi racks or HPCi PCs, a DGM200C data concentrator should be installed
-
at least one DGM200P PCI board in the ibaPDA PC
The DGM200 components have to be obtained exclusively from GE Energy Power Conversion (http://www.gepowerconversion.com).
Available modules
When the DGM200P interface license is released in the dongle, you may configure the following modules in ibaPDA:
-
HPCi Lite
-
Access on all data configured on the DGM200 bus by the CCM.
-
Access on data of all time classes of the DGM200 bus
-
max. 1000 analog values + 1000 digital values per module
-
Comfortable data selection via signal browser in the ibaPDA I/O Manager (
toc.inirequired, created by P80i address book generator)
-
Note |
|
|---|---|
|
Up to two DPM200P cards are supported in an ibaPDA PC. With HPCi Lite, you can use different address books (one per DGM200P card). Thus, access on separate DGM200 networks is provided. |
|
-
DGM200P
-
Access on data of the DGM200P memory by physical addressing (offset / data type)
-
max. 1000 analog values + 1000 digital values per module
-
Applies to special cases
-
-
DGM200P dig512
-
Access on data of the DGM200P memory by physical addressing (offset / data type)
-
max. 32 x 16 = 512 bits per module, no analog values
-
Applies to special cases
-
A maximum of up to 1024 modules are supported per interface.
Total number of signals to be measured is only limited by the ibaPDA license and performance of the involved systems.