Using the Text shift register module, the last 1 to 64 values of other text signals can be saved. The current value of one or more text signals is applied to the shift register with a trigger signal (rising edge). You can set the configuration in the I/O Manager under the node Virtual.

The required text signals must have been created beforehand with the different modules.

The memory depth of the shift register ([1]... [n]) can be adjusted from 1 to 64.

The shift register module provides all tab contents indexed as new text signals (text a [1], text a [2], ... text a [n], with n = depth of the shift register)

The values in the shift register are moved with a trigger signal (rising edge of a digital signal).

All texts contained in the shift register can be used independently of each other, e. g., for display purposes.