The basic settings and the settings under Advanced can be adjusted as usual.
For notes on the general module settings see General module settings.
Text encoding
ibaPDA supports different text encodings for the output of texts or strings.
-
Default system locale As specified in the Windows settings
-
Western European (1252): Code page for Western Europe
-
UTF-8: Unicode
Select the desired encoding here.
Connection settings
The following settings must be made for the connection:
Destination address
Here specify the destination address of the system with which the connection should be established.
Port number
Here specify the port via which the target system should communicate.
Update time
Update time determines in which cycle ibaPDA sends telegrams. If the update time is set to 0 ms, then ibaPDA sends a telegram as soon as output data is available. As for all output modules, the shortest cycle is 50 ms (see calculation time base).
Send mode
The selected send mode determines when ibaPDA should send the data.
-
Cyclic: A telegram is sent at the set update time, at least every 50 ms.
-
On change: A telegram is sent each time the signal data is changed.
-
On trigger: A telegram is sent each time a rising edge is detected on the trigger signal.